Suggested Improvements to Data Run Operations --------------------------------------------- (collected during and after S2 run) Formalize investigation/search activities for "quiet" scimon shift times Automation of plot creation / storage without deterring examination Automated production of combined RDS for inter-site correlation studies Combine calibration curves and drift corrections into single file Setting reference states for 1-button conlog comparisons More attention given to describing data quality of segments day-by-day (1-minute science mode minimum) More wall & CRT displays with figures of merit Lower-threshold communication between the sites (e.g., computer chat room) DMT improvements: More info from SenseMon (integrand, cumulative integral, other masses) Background trending from BicoMon Dedicated suspensions monitor More flexible alarm handling (e.g., silencing with timeout) Displaying glitch rates & other quality measures after common mode commences, not waiting until science mode. Allows operator to tweak. Have common mode state vector bit set AFTER common mode script finishes